Radiotherapy

Beam data measurement
Beam data measurement of a linear accelerator using 3D water phantom.

Conventional Linear Accelerator or Tomotherapy

  • Dosimetry
  • Safety interlocks
  • Mechanical checks
  • Radiation Survey

Treatment planning system

HDR remote afterloader

Diagnostic Radiology

Aluminum Step Wedges
Aluminum Step Wedges are used for measurement and analysis of x-ray beam quality

General x-ray (partial list of tests)

  • Beam alignment and collimation
  • Tube potential (kVp) accuracy and reproducibility
  • Beam filtration verification
  • High-contrast spatial resolution
  • Low-contrast sensitivity performance
  • Radiation exposure rates for typical exams and maximum output
  • Patient dose display verification
  • Automatic exposure rate control
  • Scattered radiation to operators
  • Measurement of x-ray tube leakage
  • Radiation Survey
Computed Tomography
Computed Tomography

Computed Tomography (partial list of tests)

  • Alignment accuracy
  • Table increment accuracy
  • Image thickness accuracy
  • CT number accuracy
  • High-contrast spatial resolution
  • Low-contrast performance
  • Image uniformity
  • Image noise
  • Artifact evaluation
  • Radiation dosimetry (CTDIvol) for common exams
mammography machine
High-contrast spatial resolution test of Mammography machine

Mammography machine (partial list of tests)

  • Unit assembly evaluation
  • Beam alignment and collimation
  • High-contrast spatial resolution
  • Tube potential (kVp) accuracy and reproducibility
  • Beam quality (HVL) verification
  • Radiation exposure reproducibility
  • Breast entrance exposure and average glandular dose
  • Automatic exposure control (AEC) performance
  • Image quality evaluation
  • Artifact evaluation
MRI Scanner
Image QA of MRI Scanner

MRI Scanner (partial list of tests)

  • Slice position and localization accuracy
  • Geometric accuracy
  • Image thickness accuracy
  • Magnetic field homogeneity
  • High-contrast spatial resolution
  • Low-contrast detectability
  • Image uniformity
  • Artifact evaluation
  • Performance evaluation on commonly used RF coils (SNR, uniformity, ghosting)
  • Acquisition display gray level performance
  • MRI safety program assessment

Nuclear Medicine

(partial list of tests)
Dose Calibrator
Dose Calibrator

 Instrumentation review, calibration and quality assurance

  • Dose Calibrators
  • Well Counters and Uptake Probes
  • Survey Meters
  • Gamma Cameras – Planar, SPECT, SPECT-CT
  • PET-CT/MR Systems